Hello!Welcome to Madshen.
hotsearch
MDSB316E series operation end switch isolation type safety g

 

undefined

 function

MDSB316E series operation end Isolation type conversion Safety gate  The voltage or current signal, receiving a safe place after isolation, converted into voltage or current signal output to the user specified, dangerous area. Optional One enter OneA, One enter Two A, Two enter Two A. Isolated gate From the terminal energy into the limit of intrinsically safe dangerous places, so as to ensure the safety and explosion-proof system.

 

Type specification

Product model

1 input code

2 input code

The output of the 1 code

The output of the 2 code

MDSB316E-

1:0~1VDC

1:0~1VDC

1:0~1VDC

1:0~1VDC

2:0~5VDC

2:0~5VDC

2:0~5VDC

2:0~5VDC

3:1~5VDC

3:1~5VDC

3:1~5VDC

3:1~5VDC

4:0~10VDC

4:0~10VDC

4:0~10VDC

4:0~10VDC

A:0~10mADC

A:0~10mADC

A:0~10mADC

A:0~10mADC

B:0~20mADC

B:0~20mADC

B:0~20mADC

B:0~20mADC

C:4~20mADC

C:4~20mADC

C:4~20mADC

C:4~20mADC

G: other signals

G: other signals

G: other signals

G: other signals


0: input 2


0: output 2

 

  Undefined

Explosion-proof technology index

Explosion proof mark: [Exia Ga] II C

Authentication parameters: (terminal 4/6 Between, 1/3 Between)

Um=250V Uo=28V Io=93mA

Po =655mW Co=50nF Lo=2.4mH

Product features:

The input and output power, the three party is completely isolated, strong anti-interference ability

High precision, high linearity, high stability

Modular design, small volume, low power consumption, suitable for intensive installation

Reasonable structure, easy plugging, installation, disassembly and maintenance is more convenient and simple


Technical indicators

The working power supply: 24VDC . 10%

Work    Consumption: less than or equal to 0.8W ( One enter One A)

Less than or equal to 1.6W ( One enter Two A)

Less than or equal to 2.0W ( Two enter Two A)

Input signal: DC current or voltage signal, the safety zone

Input impedance: the input current is less than or equal to Two hundred Omega;

The input voltage is greater than or equal to 500K Omega

Output signal: DC current or voltage signal, the danger zone

Output: output current, 0~650 Omega;

The output voltage is greater than or equal. 10K Omega

Conversion accuracy: + 0.1%F.S

Temperature drift:. 0.01% F.S/ C

Dielectric strength: input / The output is more than 2000VAC ( 1min )

output / The power is greater than or equal to 2000VAC ( 1min )

          input / The power is greater than or equal to 1000VAC ( 1min )

          Intrinsically safe / Non intrinsically safe, more than 2000VAC ( 1min )

Insulation resistance: input / output / The power is greater than or equal to 100M (omega 500VDC )


Product features:

The input and output power, the three party is completely isolated, strong anti-interference ability

High precision, high linearity, high stability

Modular design, small volume, low power consumption, suitable for intensive installation

Reasonable structure, easy plugging, installation, disassembly and maintenance is more convenient and simple

Common specifications selection examples:

 

Model:MDSB316E-20C0

Input: 0-5VDC signal

Output1:4-20mADC signal

Aux.power:24VDC

Description: This product is a type of operation of DC power supply converterquarantineSafety gate,      0-5VDC  signalInput,  After isolating the conversion output 4-20mADC  signalThe auxiliary power supply for 24VDC.;

For details please download: MDSB316E series of operation end Isolated gate   

Tags: MDSB316E   operation end switch isolation type safety grid  
Browse:
Return To The Top

分享到: