function
MDSB304E series The thermal resistance temperature isolation type Safety gate Received a dangerous place Three Wire Pt100 ,Cu50 , Cu100 , Pt50 Or other types of Thermal resistance signal, after linearization, transform into linear voltage or current signal output and temperature. Optional One enter One A, One enter Two A. Online index number and temperature range. Isolated gate From the terminal energy into the limit of intrinsically safe dangerous places, so as to ensure the safety and explosion-proof system.
Type specification
Product model | 1 input code | 2 input code | The output of the 1 code | The output of the 2 code |
MDSB304E- | 1:Pt100 thermal resistance | 0: input 2 | 2:0~5VDC | 2:0~5VDC |
2:Cu50 thermal resistance |
| 3:1~5VDC | 3:1~5VDC |
3:Cu100 thermal resistance |
| B:0~20mADC | B:0~20mADC |
4:Pt50 thermal resistance |
| C:4~20mADC | C:4~20mADC |
G: other thermal resistance |
| G: other signals | G: other signals |
|
|
| 0: output 2 |

Explosion-proof technology index
Explosion proof mark: [Exia Ga] II C
Authentication parameters: (terminal 1/4 , 1/6 , 4/6 Between)
Um=250V Uo=6.6V Io=68mA
Po=113mW Co=5 Mu F Lo=5mH
Technical indicators
The working power supply: 24VDC . 10%
Work Consumption: less than or equal to 1.0W ( One enter One A)
Less than or equal to 1.5W ( One enter Two A)
Input signal: Cu50 , Pt100 , Cu100 , Pt50 And the danger zone
The excitation current is less than or equal to: 0.2mA
The lead wire resistance is less than or equal to: Twenty Omega / Line
Output signal: DC current or voltage signal, the safety zone
Output: output current, 0~350 Omega
The output voltage is greater than or equal. 10K Omega
Conversion accuracy: + (0.2%F.S Delta R>40 Omega )
. 0.4%F.S (40 Omega = Delta R More than Twenty Omega )
Temperature drift:. 100ppm/ C
Dielectric strength: input / The output is more than 2000VAC ( 1min )
input / The power is greater than or equal to 2000VAC ( 1min )
output / The power is greater than or equal to 1000VAC ( 1min )
Intrinsically safe / Non intrinsically safe, more than 2000VAC ( 1min )
Insulation resistance: input / output / The power is greater than or equal to 100M (omega 500VDC )
Remarks: Safety gate The thermal resistance between the wire and the wire must be the same length, conductor resistance value will not increase the measurement error.
One enter One A model, Eleven , Twelve Don't pick feet up.
Product features:
The input and output power, the three party is completely isolated, strong anti-interference ability
High precision, high linearity, high stability
Modular design, small volume, low power consumption, suitable for intensive installation
Reasonable structure, easy plugging, installation, disassembly and maintenance is more convenient and simple
Common specifications selection examples:
Model:MDSB304E-10C0
Input: PT100 indexing signal
Output1:4-20mADC signal
Aux.power:24VDC
Description: This product is a DC power supply type heat resistancequarantineSafety gate, PT100 indexing signal Input, After isolation after transmission output4-20mADCThe auxiliary power supply for 24VDC. signal;
For details please download: MDSB304E series thermal resistance temperature Isolated gate
Tags:
MDSB304E,热电阻温变,隔离式安全栅
Browse: