function
MDSB318E series frequency transducer Isolated Safety gate The frequency of signal, receiving a dangerous place after isolation, transformed into linear output signal specified by the user. Optional One enter One A, One enter Two A. Isolated Safety gate From the terminal energy into the limit of intrinsically safe dangerous places, so as to ensure the safety and explosion-proof system.
Type specification
Product model | 1 input code | 2 input code | The output of the 1 code | The output of the 2 code |
MDSB318E- | 1: passive pulse | 0: input 2 | C:4~20mADC | C:4~20mADC |
2:24V/0V voltage pulse |
| G: other signals | G: other signals |
4:5V/0V voltage pulse |
|
| 0: output 2 |
G: other signals |
|
|
|

Explosion-proof technology index
Explosion proof mark: [Exia Ga] II C
Authentication parameters: (terminal 4/6 Between)
Um=250V Uo=28V Io=93mA
Po =655mW Co=50nF Lo=2.4mH
Product features:
The input and output power, the three party is completely isolated, strong anti-interference ability
High precision, high linearity, high stability
Modular design, small volume, low power consumption, suitable for intensive installation
Reasonable structure, easy plugging, installation, disassembly and maintenance is more convenient and simple
Technical indicators
The working power supply: 20~30VDC
Work Consumption: less than or equal to 1.2W ( One enter One A)
Less than or equal to 1.8W ( One enter Two A)
input Signal voltage pulse
High level 16~30V Low level. 0~ 5V
input Signal: 5V/0V Voltage pulse
High level 3.5~5.5V Low level. 0~0. 5V
Input signal: passive pulse (dry contact),
short-circuit current Less than or equal to 8mA The open circuit voltage. Less than or equal to 8V
Pulse width: More than 10us
Frequency range: 0.1Hz~100KHz (order specified)
(below 0.1Hz As 0Hz Processing)
Please download the data selection: MDSB318E series frequency transmission gelizha