Hello!Welcome to Madshen.
hotsearch
MDSB318E series pulse transform isolation security grid

 undefined

function

MDSB318E series pulse isolation type conversion Safety gate  DC voltage or current signal, receiving a dangerous place after isolation, transformed into frequency signal output. OptionalOne enter One A, One enter Two A. Isolated gate From the terminal energy into the limit of intrinsically safe dangerous places, so as to ensure the safety and explosion-proof system.


Type specification

 

Product model

1 input code

2 input code

The output of the 1 code

The output of the 2 code

MDSB318E-

C:4~20mADC

0: input 2

1: passive pulse

1: passive pulse

4:0~10VDC


2:24V/0V voltage pulse

2:24V/0V voltage pulse

G: other signals


4:5V/0V voltage pulse

4:5V/0V voltage pulse



G: other signals

G: other signals




0: output 2

 

 

 

 

 

 

  Undefined

 

Explosion-proof technology index

Explosion proof mark: [Exia Ga] II C

Authentication parameters: (terminal 4/6 Between)

Um=250V Uo=28V Io=93mA

Po =655mW Co=50nF Lo=2.4mH

 

 

Product features:

The input and output power, the three party is completely isolated, strong anti-interference ability

High precision, high linearity, high stability

Modular design, small volume, low power consumption, suitable for intensive installation

Reasonable structure, easy plugging, installation, disassembly and maintenance is more convenient and simple

 

 

Technical indicators

The working power supply: 20~30VDC

Work    Consumption: less than or equal to 1.2W ( One enter One A)

Less than or equal to 1.8W ( One enter Two A)

Input signal: DC voltage or current

Input impedance: input voltage, More than 500K.

          Current input, Less than or equal to 200.

output Signal: 24V/0V Voltage pulse

High level 16~30V Low level. 0~ 5V

output Signal: 5V/0V Voltage pulse

High level 3.5~5.5V Low level. 0~0.5 V

Output signal: passive pulse (open collector)

Loop current Less than or equal to Thirty MA Loop, voltage Less than or equal toThirty V

Pulse width: More than 10us

Frequency range: 0.1Hz~100KHz (order specified)

(below 0.1Hz As 0Hz Processing)

Response time: 1s ( 0~90%F.S )

Output precision: + 0.1%F.S

Temperature drift: C + 0.01% F.S/

Insulation resistance: More than 100M Omega /500VDC

Dielectric strength: input - Output, 2000VAC/1min

input - Power Supply, 2000VAC/1min

output - Power Supply, 1000VAC/1min

Intrinsically safe / Non intrinsically safe, more than 2000VAC ( 1min )

Remarks: One enter One A model, Eleven , Twelve Don't pick feet up.

 

Please download the data selection: MDSB318E series pulse conversion gelizha


 

 

 

 

Annex:

Browse:
Return To The Top

分享到: