Hello!Welcome to Madshen.
hotsearch
MDSB305E series potentiometer transmission safety barrier

 

undefined


function

MDSB305E series Transmission isolation type potentiometer Safety gate  The receiving of dangerous places (slide wire potentiometer) signal, after the isolation process, transform into a linear voltage or current signal output and resistance.Optional One enter One A, One enter Two A. Isolated gate From the terminal energy into the limit of intrinsically safe dangerous places, so as to ensure the safety and explosion-proof system.


Type specification

Product model

1 input code

2 input code

The output of the 1 code

The output of the 2 code

MDSB305E-

1:0~100 potentiometer

0: input 2

2:0~5VDC

2:0~5VDC

2:0~1k potentiometer


3:1~5VDC

3:1~5VDC

3:0~5k potentiometer


B:0~20mADC

B:0~20mADC

4:0~10k potentiometer


C:4~20mADC

C:4~20mADC

5:0~20k potentiometer


G: other signals

G: other signals

G: other resistance



0: output 2

 

  Undefined

Explosion-proof technology index

Explosion proof mark: [Exia Ga] II C

Authentication parameters: (terminal 1/4 , 1/6 , 4/6 Between)

Um=250V Uo=6.6V Io=68mA

Po=113mW Co=5 Mu F Lo=5mH


Product features:

The input and output power, the three party is completely isolated, strong anti-interference ability

High precision, high linearity, high stability

Modular design, small volume, low power consumption, suitable for intensive installation

Reasonable structure, easy plugging, installation, disassembly and maintenance is more convenient and simple

Technical indicators

The working power supply: 24VDC . 10%

Work    Consumption: less than or equal to 1.0W ( One enter One A)

Less than or equal to 1.5W ( One enter Two A)

Input signal: the maximum range 0~20 K Omega, danger zone

The excitation current is less than or equal to: 2mA

Output signal: DC current or voltage signal, the safety zone

Output: output current, 0~350 Omega

The output voltage is greater than or equal. 10K Omega

Conversion accuracy: + 0.2%F.S

Temperature drift:. 150ppm/ C

Dielectric strength: input / The output is more than 2000VAC ( 1min )

input / The power is greater than or equal to 2000VAC ( 1min )

          output / The power is greater than or equal to 1000VAC ( 1min )

          Intrinsically safe / Non intrinsically safe, more than 2000VAC ( 1min )

Insulation resistance: input / output / The power is greater than or equal to 100M (omega 500VDC )

Remarks: One enter One A model, Eleven , Twelve Don't pick feet up.

 

Common specifications selection examples:


Model:MDSB305E-10C0

Input: 0-1000 Omega potentiometer signal

Output1: 4-20mADC signal

Aux.power:24VDC

Description: This product is a variable into a DC power supply type potentiometer quarantine Safety gate ,    0-1000 Omega potentiometer  Input, After isolation after transmission output 4-20mADC The auxiliary power supply for 24VDC. signal;

For details please download: MDSB305E series potentiometer transmission Isolated gate  


Tags: MDSB305E   potentiometer change   isolation type safety grid  
Browse:
Return To The Top