Hello!Welcome to Madshen.
hotsearch
MDSC6103 series of thermocouple temperature transmitter

  Summary

MDSC6000 series AC power supply signal conditioner for power supply products work 220VAC ,

Do not need additional DC power supply, easy to use, and reduce the system cost greatly.

  Undefined

main products

MDSC6103  Thermocouple temperature Transmitter

MDSC6104 Heat resistance temperature Transmitter

MDSC6105 Slide wire resistance Transmitter

MDSC6106 Signal conversion isolator

MDSC6107 Power conversion isolator

MDSC6108 Switch isolator

MDSC6109 Switch isolator (large capacity output)

 

Installation method: 35mm Rail clamp

Connection mode: M4 Screw

 

The use of the environment

Working temperature: 0~ Fifty C

Storage temperature: -40~ Eighty-five C

Relative humidity: 10~90%RH

Atmospheric pressure: 86~106kPa

 

 

MDSC6103 Thermocouple temperature Transmitter

 

function

The scene K , S , E , B , R , T , J , N Thermocouple etc. sensor The output signal, After isolating the linear processing, and converted into a linear relationship between the voltage or current signal output and temperature. Optional One enter One A, Oneenter Two A. Online index number and temperature range.The thermocouple temperatureTransmitterWidely used in mechanical, electrical, electric power, petroleum, chemical industry, iron and steel, sewage treatment, building construction and other fields of data acquisition, signal conversion, PLC, DCS and other industrial control system, to improve and complement the system simulation, /O plug-in function, increase system reliability and applicability of the field environment.

 

Type specification

Company code

1 input code

2 input code

The output of the 1 code

The output of the 2 code

MDSC6103-

1:K type thermocouple

0: input 2

2:0~5VDC

2:0~5VDC

2:S type thermocouple


3:1~5VDC

3:1~5VDC

3:E type thermocouple


B:0~20mADC

B:0~20mADC

4:B type thermocouple


C:4~20mADC

C:4~20mADC

5:R type thermocouple


G: other signals

G: other signals

6:T type thermocouple



0: output 2

7:J type thermocouple




8:N type thermocouple




G: other thermocouple




 

 

technical parameter

The working power supply: 220VAC . 20%

Work    Consumption: less than or equal to 2VA ( One enter One A)

Less than or equal to 3VA ( One enter Two A)

Input signal: K , S , E , B , R , T , J

Cold end compensation: 0~50 Degree of error One C

Output signal: DC voltage or current signal

Output: output current, 0~350 Omega

The output voltage is greater than or equal. 10K Omega

Conversion accuracy: + (0.2%F.S Delta V>10mV)

           . 0.4%F.S (10mV More than Delta V More than 5mV)

Temperature drift:. 100ppm/ C

Dielectric strength: input / output / Power Supply, More than 1500VAC ( 1min )

Insulation resistance: input / output / Power Supply, More than 100M Omega ( 500VDC )


Remarks: isolator The thermal resistance between the wire and the wire must be the same length, conductor resistance value will not increase the measurement error.

 

One enter One A model, Thirteen , Fourteen Don't pick feet up.

Common specifications selection examples:

 

Model:MDSC6103-10C0

Input: K graduated No.

Output1:4~20mAdc

Aux.power:220VAC

Description: This product is a type of AC power supplyThermocouple temperatureTransmitterK type thermocouple, temperature signal input isolation transmission output 4~20mAdc DC current signal; auxiliary power supply for AC 220VAC.

For details please download: MDSC6103 Thermocouple temperature Transmitter