MDSE105 series Direct current Transmitter The DC current is detected in proportion to convert the DC voltage or current signal.

 

Specifications

 

Direct current Transmitter

Input current code

Output signal code

The auxiliary power supply + function code

MDSE105-

1:0~1A

1:0~5V

11:DC24V

2:0~2A

2:1~5V

31:AC220V

3:0~5A

3:0~20mA


4:0~10A

4:4~20mA


0 other ranges:

0 other ranges:


 

 Undefined

 

Technical indicators


Input signal: Direct Current, see table

Input power absorption: Less than or equal to 0.1VA (input 5A )

Input overload capacity: Two Times of continuous input current

Thirty Times, One Second current input

Output signal: DC voltage or current, see table

Output: output voltage, load or load 5K Omega

The current output load is less than or equal to Five hundred and fifty Omega

Conversion accuracy: + 0.2%F.S

Response time: 10ms

Isolation mode: input, output, power supply isolated

Insulation resistance: Twenty 0M Omega /DC500V

Dielectric strength: input / output / Power Supply 2000VAC/1min

The auxiliary power supply: DC24V . 10% Less than or equal. 1W

AC86~265V Less than or equal. 3VA

 

 