Hello!Welcome to Madshen.
hotsearch
MDSE101 series frequency transducer

 Function overview

Using single chip as the core, using the new algorithm, realize the accurate measurement of AC circuit frequency, In proportion to convert the DC voltage or current signal .

 

Specifications

frequency Transmitter

Input voltage code

Output signal code

Input frequency range

The auxiliary power source code

MDSE101-

1:100V + 40%

1:0~5V

1:45~55Hz

1:DC24V

2:220V + 40%

2:1~5V

2:48~52Hz

3:AC220V

3:270V + 40%

3:0~20mA

3:40~60Hz


4:380V + 40%

4:4~20mA

4:45~65Hz


0 other ranges:

0 other ranges:

0 other ranges:


 

 

 

 Undefined

 

Technical indicators


Signal input: AC voltage within a certain range, see table

Input power: less than or equal to absorption 0.22VA (input 220V )

Less than or equal to 0.11VA (input 100V )

Input overload capacity: Two Times (continuous)

Output signal: DC voltage or current, see table

Output: output voltage, load or load 5K Omega

The current output load is less than or equal to Five hundred and fiftyOmega

Conversion accuracy: + 0.2%F.S

Response time: 300ms

Isolation mode: input, output, power supply isolated

Insulation resistance: 200M Omega /DC500V

Dielectric strength: input / output / Power Supply 2000VAC/1min

The auxiliary power supply: DC24V . 10% Less than or equal. 1W

AC86~265V Less than or equal. 3VA



Browse:
Return To The Top