Summary
MDSC6000 series AC power supply signal conditioner for power supply products work 220VAC ,
Do not need additional DC power supply, easy to use, and reduce the system cost greatly.

main products
MDSC6103 Thermocouple temperature Transmitter
MDSC6104 Heat resistance temperature Transmitter
MDSC6105 Slide wire resistance Transmitter
MDSC6106 Signal conversion isolator
MDSC6107 Power conversion isolator
MDSC6108 Switch isolator
MDSC6109 Switch isolator (large capacity output)
Installation method: 35mm Rail clamp
Connection mode: M4 Screw
The use of the environment
Working temperature: 0~ Fifty C
Storage temperature: -40~ Eighty-five C
Relative humidity: 10~90%RH
Atmospheric pressure: 86~106kPa
MDSC6103 Thermocouple temperature Transmitter
function
The scene K , S , E , B , R , T , J , N Thermocouple etc. sensor The output signal, After isolating the linear processing, and converted into a linear relationship between the voltage or current signal output and temperature. Optional One enter One A, Oneenter Two A. Online index number and temperature range.The thermocouple temperatureTransmitterWidely used in mechanical, electrical, electric power, petroleum, chemical industry, iron and steel, sewage treatment, building construction and other fields of data acquisition, signal conversion, PLC, DCS and other industrial control system, to improve and complement the system simulation, /O plug-in function, increase system reliability and applicability of the field environment.
Type specification
Company code | 1 input code | 2 input code | The output of the 1 code | The output of the 2 code |
MDSC6103- | 1:K type thermocouple | 0: input 2 | 2:0~5VDC | 2:0~5VDC |
2:S type thermocouple |
| 3:1~5VDC | 3:1~5VDC |
3:E type thermocouple |
| B:0~20mADC | B:0~20mADC |
4:B type thermocouple |
| C:4~20mADC | C:4~20mADC |
5:R type thermocouple |
| G: other signals | G: other signals |
6:T type thermocouple |
|
| 0: output 2 |
7:J type thermocouple |
|
|
|
8:N type thermocouple |
|
|
|
G: other thermocouple |
|
|
|
technical parameter
The working power supply: 220VAC . 20%
Work Consumption: less than or equal to 2VA ( One enter One A)
Less than or equal to 3VA ( One enter Two A)
Input signal: K , S , E , B , R , T , J
Cold end compensation: 0~50 Degree of error One C
Output signal: DC voltage or current signal
Output: output current, 0~350 Omega
The output voltage is greater than or equal. 10K Omega
Conversion accuracy: + (0.2%F.S Delta V>10mV)
. 0.4%F.S (10mV More than Delta V More than 5mV)
Temperature drift:. 100ppm/ C
Dielectric strength: input / output / Power Supply, More than 1500VAC ( 1min )
Insulation resistance: input / output / Power Supply, More than 100M Omega ( 500VDC )
Remarks: isolator The thermal resistance between the wire and the wire must be the same length, conductor resistance value will not increase the measurement error.
One enter One A model, Thirteen , Fourteen Don't pick feet up.
Common specifications selection examples:
Model:MDSC6103-10C0
Input: K graduated No.
Output1:4~20mAdc
Aux.power:220VAC
Description: This product is a type of AC power supplyThermocouple temperatureTransmitterK type thermocouple, temperature signal input isolation transmission output 4~20mAdc DC current signal; auxiliary power supply for AC 220VAC.
For details please download: MDSC6103 Thermocouple temperature Transmitter
Browse: