MDSVP5600 series Intelligent valve positioner By the intelligent two-wire field instrument design and technology in the United States launched China, as an important supporting pneumatic valve control Parts are widely used in petroleum, chemical, electric power, metallurgy, light industry and other fields.
The electrical structure principle of 1 and MDSVP, to avoid the output of traditional positioner due to mechanical characteristics bring concussion, the zero drift of unstable performance weaknesses, makes the valve control More stable.2, the German original piezoelectric valve action time<20ms, high positioning accuracy, can be reduced due to inaccurate positioning of the valve opening shock, lifting valve control Precision.3, the valve characteristic curve and MDSVP correction process control Function can be extended range of application of the valve.4, MDSVP uses a special structural design, the formation of internal pressure in the microseismic cut off the external cavity of the gas permeability, and more adapt to the complex and harsh working conditions.5, MDSVP electric conversion unit with machinery, fully sealed structure, the German original piezoelectric valve average fault free switching frequency up to 2 billion times, high reliability.6, MDSVP with a flow adjusting device, can accurately through the base knob control Input to the implementation of air flow organization, so as to eliminate the oscillation of small capacity actuator.7, MDSVP comes with three valvestermination, without external electromagnetic valve, lock valve and other accessories can achieve the valve position switch or linkage switch output self regulating valve, to avoid failure and endanger production.8, MDSVP the latest U.S. electric conversion technology and the German original piezoelectric valve group, the steady-state air consumption of less than 36 liters per hour (conventional positioner for 400 l / h), a year can save more than 1400 electricity (the national standard of petrochemical energy consumption calculation).In 9, MDSVP in 1 minutes self-tuning zero and travel, on-site training without external signal source; large volume applications, can communication Download all operating parameters; only 3 buttons to complete.10, MDSVP with 7 double word LCD, rotating opening and optional pressure gauge display, clear and intuitive reaction of site conditions.Emergency mode, 11 unique to MDSVP, can not open the closed shell in the absence of direct manual operation valve.


Model |
| MDSVP500 | MDSVP5500 | MDSVP5600 |
Piezoelectric valve | Place of Origin | Altenstadt |
Model | P6 series | P9 series |
Gas index | Air standard | accord with ISO 8573-1Solid particle size and density level TwoOil concentration level: TwoThe dew point pressure: Two Or at least less than the minimum ambient temperature 10K |
Air pressure | 0.14~0.7Mpa |
Leakage | <0.6L/H |
Steady state consumption | <36L/H |
Input and output | Adaptive actuator | Single and double action |
Travel range | Straight trip 10~100mm Angular travel; 30~120° |
Input signal | 4~20mA The minimum input current. 3.6mA Can set the branch; control start and finish |
Feedback signal | 4~20mA |
Switch input | Stem node, for self-protection interlock function |
Switch output | - | Two road 24V 2A Travel switch, Two Electronic switches | - |
Output characteristic correction | Linear, equal percentage ( One : Twenty-five , One : Thirty-three , One : Fifty ), quick opening, custom Twenty Curve |
communication mode | HART |
Display mode | LCD | Two Row Seven Word size 22× 38mm |
The opening show | - | 0~100% And can be rotated | - |
Pressure gauge | 2~3 Optional pressure gauge |
Configuration operation | Self tuning | Self tuning valve of zero and full scale, and to predict the minimum minimum dead |
Self diagnosis | The process of setting the valve position, the valve plug gauge |
Local manual operation | Three A button in the manual operation valve opening |
accuracy | dead zone | 0.1~10% |
Linearity | 0.5% |
sensitivity | 0.1% |
Repeatability | 0.2% |
lightning protection | Shell voltage protection level | - | Line line: 65V Line to ground: <700V |
response time | - | Line line: <4ns Line to ground: <20ns |
The impact of peak current | - | 10KA |
The impact of peak voltage | - | 20KV |
work environment | ambient temperature | -20~70 C |
Ambient humidity | 5~95%RH |
Anti vibration performance | 15~150Hz/2g |
Protection grade | IP65 |
Explosion proof grade | Exia IIcT4~T6 | Exd IIcT4~T6 |